    AS320 elevator inverter is a kind of newly developed frequency inverter especially for elevators. It is designed with 32-bit MPU for motor driving, high performance complex programmable logic device (CPLD), and advanced power module. Meanwhile, the elevator inverter is designed based on international advanced closed loop vector control technology and supports various control modes including V/F control, sensorless vector control, and torque control modes. Integrating the characteristics of potential energy load, the elevator inverter allows elevators to operate efficiently, smoothly and steadily, and offers passengers a comfortable feeling. 


    The elevator inverter is designed based on innovative load-sensorless start compensation technology, which helps ensure comfortable feeling at the starting moment without installation of a weight measuring device. Meanwhile, incremental ABZ encoder is utilized to achieve control of the synchronous motor. In addition, new type PWM inverter dead time compensation method and dynamic PWM carrier modulation technology help effectively reduce the noise and losses in electric motors. By making improvement on inverter hardware, our elevator inverters offer a maximum junction temperature of 175? and low switch loss. 


    Main Features

    1. Closed loop vector control technology ensures high performance.

    2. Zero-speed torque compensation without load weighing device helps to save cost.

    3. New PWM dead-zone compensation technology of the elevator inverter results in less energy loss.

    4. Dynamic PWM carrier modulation technology for less motor noise.


    Model

    Rated capacity (kVA)

    Rated output current (kA)

    Applicable motor power (kW)

    2S01P1

    2.3

    6.0

    1.1

    2S02P2

    4.6

    12

    2.2

    2S03P7

    6.9

    18

    3.7

    4T02P2

    4.7

    6.2

    2.2

    4T03P7

    6.9

    9

    3.7

    4T05P5

    8.5

    13

    5.5

    4T07P5

    14

    18

    7.5

    4T0011

    18

    27

    11

    4T0015

    24

    34

    15

    4T18P5

    29

    41

    18.5

    4T0022

    34

    48

    22

    4T0030

    50

    65

    30

    4T0037

    61

    80

    37

    4T0045

    74

    97

    45

    4T0055

    98

    128

    55

    4T0075

    130

    165

    75


    Technical Specifications of the Elevator Inverter 

    Item

    Technical index

    Max. output voltage (V)

    Three phase, 380/400/415/440/460V

    Input power supply

    Phase number, voltage, frequency

    Three-phase, 380/400/415/440/460V 50/60Hz

    Allowable voltage change

    -15% ~ +10%

    Allowable frequency change

    -5% ~ +5%

    Elevator inverter operation condition when voltage dips

    When voltage is AC300V or above: operate continuously When the rated input voltage drops to a voltage below AC300V: under-voltage protection is available in 15ms.

    Control characteristic

    Control mode

    Vector control with PG card V/F control Open loop vector control Torque control

    Starting torque

    150%: 0Hz (PG card vector control) 120%: 0.5Hz (V/F control) 150%: 0.5Hz (open loop vector control)

    Speed control range

    1:1000 (vector control with PG card) 1: 200 ( vector control without PG card)

    Speed control precision

    ±0.02% (vector control with PG card, 25 ±10 ?); ±0.2% (vector control without PG card 25 ±10 ?)

    Torque limitation

    Available through parameter setting

    Torque precision

    ±5%

    Frequency control range

    0 ~ 120Hz

    Frequency precision (temperature fluctuation )

    ±0.01% (Digital command, -10 ~+45? ) ±0.1% (Analog command, 25 ±10 ?)

    Preset frequency resolution

    0.01Hz (Digital command) ±0.06Hz/120Hz (Analog command, 11bit + unsigned)

    Output frequency resolution

    0.01Hz

    Overload capacity

    Zero speed: 150% , < 3Hz: 160%, > 3Hz: 200%

    Braking torque

    150% (external brake resistor), built-in brake unit

    Acceleration / deceleration time

    0.01 ~ 600s

    Carrier frequency

    2 ~ 11kHz

    Speed setting

    Digital setting, analog setting, control panel setting

    Storage battery operation

    If power failure occurs, the elevator inverter allows the elevator to work on storage batteries at a low speed, thus enabling the elevator to stop at the nearest floor

    PG card interface signal

    PG-card power supply

    5V, 12V, 300mA

    PG-card signal type

    Open collector, push-pull, differential, SIN/COS, Endat absolute types

    PG-card frequency divided output

    OA and OB orthogonal, dividing frequency coefficient: 1-128

    Control signal input/output

    Analog voltage input

    2 input channels, -10 ~ +10VDC, precision 0.1%

    Analog voltage output

    2 output channels, -10 ~ +10VDC, precision 0.1%

    Opto-isolator input

    8 input channels, input function is user-defined

    Open collector output

    4 output channels, output function is user-defined

    Programmable relay output

    2 output channels, normally open and closed contacts are available; Contact capacity: resistance: 5A 250VAC or 5A 30VDC Output function is user-defined

    RS485 communication signal

    1-channel,

    RS232 communication interface

    1-channel, used for connection to control system or PC

    Protection functions

    Motor overload protection

    The function is available through parameter setting

    Elevator inverter overload protection

    < 3Hz: 160%, 5 seconds > 3Hz : 185%, 10 seconds

    Short circuit protection

    Protect the elevator against over-current caused by short circuit of any two output phases

    In-operation input phase loss protection

    During operation, if there is input phase loss, output is stopped to protect the elevator inverter

    In-operation output phase loss protection

    During operation, if there is output phase loss, output will be stopped to protect the elevator inverter

    Over-voltage threshold

    Bus voltage 410V(200V series), 810V(400V series)

    Under-voltage threshold

    Bus voltage 180V (200V series), 380V(400V series)

    Instantaneous power off compensation

    Protection over 15ms

    Overheat of radiation fins

    Protection is available through thermistor

    Speed loss protection

    Available when the operation speed variation is over 30% of rated speed

    Impulse encoder failure protection

    Disconnect PG

    Braking unit protection

    Automatic diagnosis of braking unit failures, and then give protections

    Module protection

    Include overcurrent, short circuit and overheat protections

    Current sensor protection

    Auto detect when powered on

    Reversed-speed protection

    Detect through encoder

    I ²t protection

    Detect through 3-phase current

    Over-high input voltage protection

    400V series: > 725V 200V series: >360V Detect when stopped

    Output ground fault protection

    If there is any short circuit to ground during operation, the output will be stopped to protect the elevator inverter

    Output unbalance protection

    If there is unbalanced output current, the output will be stopped to protect the elevator inverter

    Short circuit protection for brake resistor

    Detect while braking

    Encoder interference

    Evaluate the encoder interface degree and alarm

    EEPROM failure

    Detect when powered on

    Display

    LCD display

    All sub-menus

    Operation environment

    Ambient temperature

    -10 - +45?

    Humidity

    95%RH or below (no condensing)

    Storage temperature

    -20 ~ +60? (storage during short term transportation)

    Application places

    Indoor (without corrosive gas and heavy dust)

    Altitude

    1000m or lower

    Structure

    Protection class

    IP20

    Cooling method

    Forced air cooling

    Installation method

    In cabinet


    We are a major elevator inverter manufacturer and supplier in China. We offer various types of products such as general vector inverter, elevator group control system, energy regenerator and car controller board.

    As one of the leading manufacturers and suppliers of elevator dedicated frequency converter in China, we warmly welcome you to buy our quality and durable elevator dedicated frequency converter with competitive price. We will offer you good after-sale service and fast delivery.

Send your message to this supplier
To:  

Yixin Shanghai International Trade Co.,Ltd

* Content:  

For better quotations, include:

- A self introduction

- Special requests, if any

Quantity:  

  
You May Like
Not exactly what you want? One request, multiple quotations Get Quotations Now >>